Akovoyon Samuel

Sir,I work with J.M.G.generator company in Nigeria,In assembly department.Please i will like to know more on power wizard because i assemble F.G WILSON generators thanks in advance.

Sofola Olatunde

i am staff of jmg limited in nigeria. i want to know more about power wizard panel.

Richard Lingard

I operate a generator with power wizard control unit fitted. I have a maintenance alarm indicated which will not clear. Can you advise the codes for access to reset this fault.

Thanks

Richard Lingard

Agok

I would like to know how to make PowerWizar start the generator remotely through a time switch, thanks

Eng. Ibrahim Rahman

Dear Sir
I need operation manual and wiring digram for this control panel or any other catalogs u can give and You Know its helpful
its installed with Perkins engine 4006 series and I will be very Thankful

Rabih Abourahal

Dear Sir

I have tow power wizard 2.0 control panel installed on two generators.
I want to integrate with these panels via MODBUS RTU(RS485),
Please, can you send the REGISTERS LIST of this panel.
Please advise.
Thanks.

Petr

I am developing a program control panel power wizard 2.
can you send the REGISTERS LIST of this panel ?

samson waithaka

Hey I work with excel engineering Kenya. I have a power wizard 1.0 which displays everything okey,but isn't starting the generator.On dismantling the power wizard, a diode is blown. After replacing with a similar diode, still not starting. Where is the remedy?

Dudu

powerwizard 2.0
can you send the REGISTERS LIST of this panel ?
thank you

David

Can you Please send MODBUS registers thank you

ROB STAHL

I HAVE A NEW PANEL I HAVE HAD FOR SOME TIME,I AM WANTING TO INSTALL ON A GENERATOR I PUT TOGETHER, CAN YOU TELL ME IF IT IS A 1.0, 2.0, OR 3.0 BY THE S/N 2957B752HP OR BY THE AMOUNT OF PINS (61PINS) ALSO IS THERE A LEVEL 3 PASSWORD IN NEW PANELS OR CAN I PUT IN MY OWN WITHOUT THE USE OF A EST. IF NOT WHAT KIND OF BASIC EST TOOL WILL I NEED TO AQUIRE TO DO THE JOB? THANK YOU

Rajesh K

Please help me to know whether powerwizard 1.0 can be used to synchronise four generators?(all four generators have same panel)if not what is the way out?

Ivan

I have 19 generators with power wizard 2.0 control panel installed.
I want to integrate with these panels via RS485 scada data link for remote control.
Please, can you send the REGISTERS LIST of this panel.
Please advise.
Thanks.

JF Stone

Looking for a part number for the 4 pin magnetic pickup - speed sensor -. The generator is a perkins made by FG Wilson. the wires from the sensor go to the 1.0 Power Wizard. I have a bunch of small generators needing these sensors.

ivan

powerwizard 2.0
can you send the REGISTERS LIST of this panel
thanks in advance

ROB STAHL

I BOUGHT A NEW CONTROL PANEL THRU A FREIGHT RECOVERY BUS. IT DOES NOT HAVE SOFTWARE LOADED, CAN YOU TELL ME WHERE I CAN GET IT INSTALLED PLEASE,

Lau

powerwizard 2.0
can you send REGISTER LIST of thus panel

thank you

Qadeer ahmad

Dear Sir
i am working in adpower i need the link document of power wizard 1.0 module so that i can confugration the module

otim robert

hello,
Iam working on an FGWilson genset with power wizard 1.0,the problem i have is that the Engine shutsdown showing Engine speed sensor erratic. took the magnetic pick to another engine and its perfect.I swapped another power wizrad 1.0 and EIM and the Harness from a similar genset and the Engine still shutsdown giving engine speed sensor erratic.Please whats the way out?

ANDRE LUIZ

I have generators with power wizard 2.0 control panel installed.
I want to integrate with these panels via RS485 scada data link for remote control.
Please, can you send the REGISTERS LIST of this panel.
Please advise.
Thanks.

Matthew Lord

How do i change the monitoring voltage in power wizard 2.from 400 volts three phase to 230 volts single phase? I have 12 FG Wilson set can you please advise?

Paulo Galvao

Hi,
I'm working with the Power Wizard 2.0 and I'm going to integrate it using the interface RS-485 (Modbus protocol).
Could you send me the Registers List?
Thank you!

Rehan

I need operation manual and wiring digram for this control panel or any other catalogs u can give and You Know its helpful
its installed with Perkins engine 1300 series and I will be very Thankful

ashnil

this is ashnil ca i now your email address

ashnil

i want to now more about power wizard 2.0 generators